Shoe-Railing System
Project detail
Similar or Equivilant to CR Laurence “GRS System”
Must support Surface Mount / Embed Mount / Fascia Mount
Typical Performance Requirements for Handrail Assembly:
- Support distributed load of 50 pounds per linear foot (0.73kN/M), applied horizontally at right angles in any direction to the handrail.
- Support concentrated horizontal load of 200 pounds (0.89kN), applied in any direction at any point along handrail system.
- 50 lbs (0.22kN) on 1 sf (0.093m2) perpendicular to guard at any location
- Wind loads 25 psf or as otherwise specified.
- Distributed loads and concentrated loads not to be applied simultaneously.
Systems must be versatile enough to accept a range of glazing from Monolithic lite (12mm) up to a Laminated glass (10/1.52/10)